Modification
in different versions
v2.08
Caution: After the update, the system
performs a system reset. This will delete all
calibration- and programming data. You have to calibrate and reprogramm the
system
after the update. Please check, if you need the new functions in v2.08
Variable
socket: If you change from a variable to a static socket, you´ve
seen furthermore the
value of the variable socket in the display.
Timer:
You can now set 32 different procedures whith different
values to one variable socket.
Intervall:
Like timer: 32 different procedure on one socket.
External
display: Blank between day and date insertet
Control:
After disabling a controlfunction, the system does not
respond.
v2.09
Programming
Level: There was no difference between "normal" and profi" mode.
No mater what you
select, the system was always in the profi mode.
v2.10
Lunar
Phase : Problems in simulation mode "on" - Timezone wasn´t
recognized
Conductivity
: New conductivity display options "salinity" and "density"
v2.11
Conductivity
: There was an error on calibrating on temperature other than 25°C.
v2.11a
(English version only)
Translation:
New menu text
v2.11a
(French version only)
Translation:
There was an error by few words in the display text
v2.12
Day/Night-Simulation:
Using a socket with power regulation causes the socket go off for a small
time
period at the beginning of the sunset
v2.13
O2:
O2-Measurement needs at minimum this version
v2.14
O2:
If calibrating of oxygen modul was not successful and "Buffer: 100" don't
appears on the display, it has had to carry
out a so-called Reset . This has erased all former programming.
DO NOT DOWNDATE from v2.15 to v2.14 ! !
!
v2.15
Softwareversion
for new aquastar hardware. No additional software functions.
v2.16
Caution: After the update, the system
performs a system reset. This will delete all
calibration- and programming data. You have to calibrate and reprogramm the
system
after the update. Please check, if you need the new functions in v2.16.
manual
and automatic feeding break. (supplementary sheet (feeding
break))
Day/Night--Simulation
for static sockets are now able to be switched off .
When
operating in conjunction with a daytime/night-time simulation,
a switchable socket switches on 30 minutes
after sunrise and then switches off when the sun begins
to set ( 30 minutes before the time set for "Off").
iks aquastar version 2.16 english (
75 kB )
v2.17
Caution: After the update, the system
performs a system reset. This will delete all
calibration- and programming data. You have to calibrate and reprogramm the
system
after the update. Please check, if you need the new functions in v2.17.
Manual,
half-automatic and automatic feeding break.
As
soon as 2000 measurement chains were stored, the oldest measurement
chains are written over.
Feeding
break caused an error at the current (high/low tide) simulation
at variable-output sockets.
If
data (chains of measurement) is transferred to a PC, the
memory (data) is not automatically cleared. Erasing
memory is done with the aquastar menu item "Measurement
settings - memory" or with the software
winsoft v0.17.2 .
aquastar
software v2.17 is compatible to winsoft v0.17.2 concerning
the menu item "Read programming data" and "Write
programming data" .
iks aquastar version 2.17 english (
75 kB )
v2.18
In
extremely rare cases a sensor error arose with version 2.17 even with new
oxygen sensors during the calibration.
v2.19
Caution: After the update, the system
performs a system reset. This will delete all calibration- and programming
data. You have to calibrate and reprogramm the system after the update. Please
check, if you need the new functions in v2.19. Only compatible with winsoft
V0.19.0
pH
control with delay time (e.g. for garden ponds)
Menu
item "SetMeasurement - Display - Temperature: °C or °Fahrenheit.
If Display "°Fahrenheit" is chosen,
then the stored data and the regulation values have the same unit
of measurement => °F.
iks aquastar version 2.19 english (
76 kB )
v2.20
SMS-Controller: This version is only necessary, if broadcasting a short message (SMS) with the cause "no control".
iks aquastar version 2.20 english ( 85 kB )
v2.21
If using the newest conductivity module (grey and blue housing (picture) , since june 2004) this version must be loaded.
iks aquastar version 2.21 english ( 85 kB )