Modification in different versions

  v2.08

 

Caution: After the update, the system performs a system reset. This will delete all
calibration- and programming data. You have to calibrate and reprogramm the system
after the update. Please check, if you need the new functions in v2.08


  Variable socket: If you change from a variable to a static socket, you´ve seen furthermore the
     value of the variable socket in the display.
  Timer: You can now set 32 different procedures whith different values to one variable socket.
  Intervall: Like timer: 32 different procedure on one socket.
  External display: Blank between day and date insertet
  Control: After disabling a controlfunction, the system does not respond.

  v2.09

  Programming Level: There was no difference between "normal" and profi" mode. No mater what you
     select, the system was always in the profi mode.

 

  v2.10

  Lunar Phase : Problems in simulation mode "on" - Timezone wasn´t recognized
  Conductivity : New conductivity display options "salinity" and "density"

 

  v2.11

  Conductivity : There was an error on calibrating on temperature other than 25°C.

 

  v2.11a (English version only)

  Translation: New menu text

 

  v2.11a (French version only)

  Translation: There was an error by few words in the display text

 

  v2.12

  Day/Night-Simulation: Using a socket with power regulation causes the socket go off for a small time
period at the beginning of the sunset

 

  v2.13

  O2: O2-Measurement needs at minimum this version

 

  v2.14

  O2: If calibrating of oxygen modul was not successful and "Buffer: 100" don't appears on the display, it      has had to carry out a so-called Reset . This has erased all former programming.
     DO NOT DOWNDATE from v2.15 to v2.14 ! ! !

 

  v2.15

  Softwareversion for new aquastar hardware. No additional software functions.

 

  v2.16

 

Caution: After the update, the system performs a system reset. This will delete all
calibration- and programming data. You have to calibrate and reprogramm the system
after the update. Please check, if you need the new functions in v2.16.

 

  manual and automatic feeding break. (supplementary sheet (feeding break))
  Day/Night--Simulation for static sockets are now able to be switched off .
  When operating in conjunction with a daytime/night-time simulation, a switchable socket switches on 30      minutes after sunrise and then switches off when the sun begins to set ( 30 minutes before the time set      for "Off").
     iks aquastar version 2.16 english ( 75 kB )

 

  v2.17

 

Caution: After the update, the system performs a system reset. This will delete all
calibration- and programming data. You have to calibrate and reprogramm the system
after the update. Please check, if you need the new functions in v2.17.

 

  Manual, half-automatic and automatic feeding break.
  As soon as 2000 measurement chains were stored, the oldest measurement chains are written over.
  Feeding break caused an error at the current (high/low tide) simulation at variable-output sockets.
  If data (chains of measurement) is transferred to a PC, the memory (data) is not automatically cleared.      Erasing memory is done with the aquastar menu item "Measurement settings - memory" or with the      software winsoft v0.17.2 .
  aquastar software v2.17 is compatible to winsoft v0.17.2 concerning the menu item "Read programming      data" and "Write programming data" .
     iks aquastar version 2.17 english ( 75 kB )

 

  v2.18

  In extremely rare cases a sensor error arose with version 2.17 even with new oxygen sensors during the      calibration.

 

  v2.19

 

Caution: After the update, the system performs a system reset. This will delete all calibration- and programming data. You have to calibrate and reprogramm the system after the update. Please check, if you need the new functions in v2.19. Only compatible with winsoft V0.19.0

 

  pH control with delay time (e.g. for garden ponds)
  Menu item "SetMeasurement - Display - Temperature: °C or °Fahrenheit. If Display "°Fahrenheit" is      chosen, then the stored data and the regulation values have the same unit of measurement => °F.
     iks aquastar version 2.19 english ( 76 kB )

 

  v2.20

  SMS-Controller: This version is only necessary, if broadcasting a short message (SMS) with the
     cause "no control".
     iks aquastar version 2.20 english ( 85 kB )

 

  v2.21

  If using the newest conductivity module (grey and blue housing (picture) , since june 2004) this version      must be loaded.
     iks aquastar version 2.21 english ( 85 kB )